grinding room
The grinding room can meet the needs of different repair workshops. The main function is to remove dust and exhaust gas from the repair workshop, ensure a fresh working environment, improve maintenance quality, and protect the health of production personnel.
Main design forms:
1. Equipped with air supply and exhaust systems, which are circulated and filtered through the static pressure chamber to the outside.
Fans: Two double-inlet centrifugal 5.5KW fans, with an air volume of 20,000m3/h, belt-driven, and the same for the supply and exhaust fans.
Lighting: 4×36W×8 groups.
Damper: Automatic damper for switching from circulation to exhaust.
Heating: optional with burner.
Working area size: L6300×W3450×H2700mm.
Cabinet size: L2500×W1200×H2400mm.
2. It is equipped with a single exhaust system, and the filtered air circulates directly to the outside through the static pressure chamber.
Fan: A double-inlet centrifugal 5.5KW fan with an air volume of 20,000m3/h, belt drive.
Lighting: 4×36W×8 groups.
Damper: Automatic damper for switching from circulation to exhaust.
Working area size: L6300×W3450×H2700mm.
Cabinet size: L2250×W1200×H2200mm.
3. The air filtered by the single exhaust air is directly discharged to the outside.
Fan: A double-inlet centrifugal 5.5KW fan with an air volume of 20,000m3/h, belt drive.
Cabinet size: L2250×W1200×H2200mm. Two filter systems.